● R32 / R290 Low GWP Refrigerant
Compared to the refrigerants widely used today, such as R-410A and R407C, R32 and R290 have much lower global warming potential, which helps speed up their popularity in the heat pump industry.
● Wider Running Range
Thanks to the inverter and EVI technology, the Sunpro Series Heat Pump features a wide operating temperature range to provide space heating, cooling, and domestic hot water. It can reach the high water temperature in a cold climate and work stably at ambient temperatures as low as -25℃.
● Increased Efficiency
With a maximum COP of 6.15 and an ErP rating of A+++, the Sunpro Series EVI DC inverter heat pump can charge and recirculate more efficiently. It consumes less energy and therefore helps families reduce heating bills.
● Wi-Fi Smart Control
With Wi-Fi function, the users control the heat pump anywhere and anytime:
● Full DC Inverter Technology
The Sunpro Series heat pump combines a full DC inverter twin-rotary compressor with an inverter brushless motor, so the unit can adjust target temperature automatically, to bring users maximum comfort at the lowest costs.
● Intelligent Water Temperature Adjustment
The unique control logic enables Sunspro Series to adjust the outlet water temperature intelligently, according to the real-time ambient temperature. Therefore, the heat pump can deliver heating, cooling, and domestic hot water at a constant temperature.
● Touch Screen Color LCD Display
The 4-inch color LCD display can be installed on the wall. Featured with 0.5°C precise temperature control, water temperature curve display, easy timing, one-key mute, one-key faster heating, etc, it is very user-friendly.
● Super Low Noise
In addition to brushless DC inverter fans, the Sunpro Series EVI heat pump adopts reinforced sound reduction measures such as the dual shock absorption by the famous-brand compressor. The sound levels start as low as 42dB(A), making itself the quietest system in our DC inverter lineup.
● EVI Technology
EVI stands for “Enhanced Vapor Injection” and is a technology used on our low-temperature heat pumps to achieve higher performance at lower temperatures as down as -25°C. With EVI technology and inverter compressor, the Sunpro Series can work stably and remain high efficiency.
● Global Application Potential
With the above features, the Sunpro Series heating & cooling heat pump can be widely used:
Model (NE-F) | 40HCR4INEM-SA | 60HCR4INEM-SA | 90HCR4INEM-SA | 130HCR4INEM-SA |
Power Supply (V/Ph/Hz) | 220-240V~/50Hz | |||
Refrigerant Type | R32 | |||
[Space Heating] Ambient Temperature (DB/WB): 7°C/6°C, Water Temperature (Inlet/Outlet): 30°C/35°C. | ||||
Heating Capacity (kW) | 1.69~4.12 | 1.73~6.06 | 2.32~8.65 | 3.53~12.76 |
Power Input (kW) | 0.27~0.88 | 0.28~1.31 | 0.38~1.88 | 0.58~2.83 |
COP | 6.15~4.65 | 6.13~4.61 | 6.06~4.59 | 6.01~4.51 |
[Space Heating] Ambient Temperature (DB/WB): 7°C/6°C, Water Temperature (Inlet/Outlet): 50°C/55°C. | ||||
Heating Capacity (kW) | 1.09~3.52 | 1.12~5.29 | 1.81~7.83 | 2.38~10.86 |
Power Input (kW) | 0.25~1.32 | 0.26~2.03 | 0.43~3.05 | 0.58~4.31 |
COP | 4.32~2.65 | 4.24~2.61 | 4.15~2.56 | 4.11~2.52 |
[Space Cooling] Ambient Temperature (DB/WB): 35°C / -, Water Temperature (Inlet/Outlet): 12°C/7°C. | ||||
Heating Capacity (kW) | 0.95~3.41 | 0.97~4.86 | 1.43~7.17 | 2.06~10.33 |
Power Input (kW) | 0.20~1.22 | 0.21~1.76 | 0.32~2.67 | 0.46~3.89 |
COP | 4.61~2.79 | 4.55~2.75 | 4.45~2.68 | 4.43~2.65 |
[Hot Water] Ambient Temperature (DB/WB): 20°C/15°C, Water Temperature from 15°C to 55°C. | ||||
Heating Capacity (kW) | 7.32 | 10.37 | 15.31 | |
Power Input (kW) | 1.01 | 1.51 | 2.15 | 3.21 |
COP | 4.83 | 4.83 | 4.82 | 4.76 |
ErP Level (35°C) | A+++ | |||
ErP Level (55°C) | A++ | |||
Electric Heater Rated Input(kW) | 3 | |||
Max. Power Input (kW) | 4.4(1.4+3) | 5.1(2.1+3) | 6.1(3.1+3) | 7.5(4.5+3) |
Max. Running Current (A) | 20(6.3+13.7) | 23.2(9.5+13.7) | 27.8(14.1+13.7) | 34.1(20.4+13.7) |
Circulating Pump | Built-in | |||
Fan Motor Type | DC motor | |||
Water Side Heat Exchanger | Plate Heat Exchanger (Danfoss) | |||
Air Side Heat Exchanger | Finned Heat Exchanger | |||
Expansion Tank Volume (L) | 2 | |||
Display | 4-inch Colored Touch Screen | |||
Wi-Fi Function | Yes | |||
Rated Water Flow (m³/h) | 0.7 | 1 | 1.6 | 2.1 |
Water Pressure Drop (kPa) | 15 | 17 | 20 | 22 |
Water Pipe Connection | 1" | 1" | 1 1/4" | 1 1/4" |
Sound Pressure Level at 1m dB(A) | 42~52 | 42~53 | 43~54 | 43~55 |
Operation Range (°C) | -25~43 | |||
Max. Outlet Water Temp. (°C) | 60 | |||
Water Proof Class | IPX4 | |||
Electricity Shock Proof | Ⅰ | |||
Net Dimensions (L×W×H) (mm) | 1150×450×695 | 1150×450×695 | 1338 x 450 x 870 | 1338 x 450 x 870 |
Model (NE-F) | 160HCR4INEM-SA | 180HCR4INEM-SA | 200HCR4TINEM-SA | 230HCR4TINEM-SA | 260HCR4TINEM-SA | 310HCR4TINEM-SA |
Power Supply | 380-415V/3N~/ 50Hz | |||||
Refrigerant Type | R32 | |||||
[Space Heating] Ambient Temperature (DB/WB): 7°C/6°C, Water Temperature (Inlet/Outlet): 30°C/35°C. | ||||||
Heating Capacity(kW) | 4.81~16.05 | 6.15~18.33 | 6.36~20.44 | 8.43~23.11 | 8.54~25.93 | 10.13~31.32 |
Power Input (kW) | 0.81~3.67 | 1.03~4.14 | 1.08~4.61 | 1.41~5.32 | 1.46~6.08 | 1.73~7.23 |
COP | 5.89~4.37 | 5.95~4.42 | 5.87~4.33 | 5.94~4.34 | 5.82~4.26 | 5.83~4.33 |
[Space Heating] Ambient Temperature (DB/WB): 7°C/6°C, Water Temperature (Inlet/Outlet): 50°C/55°C. | ||||||
Heating Capacity (kW) | 2.82~14.12 | 3.44~16.40 | 3.41~17.69 | 4.41~20.09 | 4.67~22.27 | 5.34~26.89 |
Power Input (kW) | 0.64~5.34 | 0.78~6.33 | 0.89~7.04 | 1.01~7.61 | 1.04~8.66 | 1.25~10.54 |
COP | 4.37~2.64 | 4.39~2.59 | 4.32~2.51 | 4.34~2.64 | 4.28~2.57 | 4.27~2.55 |
[Space Cooling] Ambient Temperature (DB/WB): 35°C / -, Water Temperature (Inlet/Outlet): 12°C/7°C. | ||||||
Heating Capacity (kW) | 2.63~13.16 | 3.12~15.13 | 3.31~16.82 | 3.80~19.01 | 4.37~21.85 | 5.03~26.39 |
Power Input (kW) | 0.59~5.02 | 0.71~5.73 | 0.76~6.44 | 0.88~7.23 | 1.02~8.40 | 1.19~10.11 |
COP | 4.41~2.62 | 4.36~2.65 | 4.32~2.61 | 4.31~2.63 | 4.25~2.60 | 4.23~2.61 |
[Hot Water] Ambient Temperature (DB/WB): 20°C/15°C, Water Temperature from 15°C to 55°C. | ||||||
Heating Capacity (kW) | 19.25 | 21.60 | 23.95 | 27.73 | 31.07 | 37.52 |
Power Input (kW) | 3.98 | 4.54 | 5.05 | 5.74 | 6.52 | 7.95 |
COP | 4.83 | 4.75 | 4.74 | 4.83 | 4.76 | 4.72 |
ErP Level (35°C) | A+++ | |||||
ErP Level (55°C) | A++ | |||||
Electric Heater Rated Input(kW) | 3 | |||||
Max. Power Input (kW) | 8.8(5.8+3) | 9.6(6.6+3) | 10.2(7.2+3) | 11.5(8.5+3) | 12.7(9.7+3) | 14.7(11.7+3) |
Max. Running Current (A) | 23.8(10.1+13.7) | 25.2(11.5+13.7) | 26(12.3+13.7) | 28.3(14.6+13.7) | 30.4(16.7+13.7) | 33.9(20.2+13.7) |
Circulating Pump | Built-in | |||||
Fan Motor Type | DC motor | |||||
Water Side HeatExchanger | Plate Heat Exchanger (Danfoss) | |||||
Air Side Heat Exchanger | Finned Heat Exchanger | |||||
Expansion Tank Volume (L) | 5 | 5 | 5 | 5 | 5 | 8 |
Display | 4-inch Colored Touch Screen | |||||
Wi-Fi Function | Yes | |||||
Rated Water Flow (m³/h) | 2.7 | 3.1 | 3.4 | 4 | 4.4 | 5.24 |
Water Pressure Drop (kPa) | 24 | 26 | 28 | 30 | 31 | 33 |
Water Pipe Connection | 1 1/4" | 1 1/4" | 1 1/4" | 1 1/2" | 1 1/2" | 1 1/2" |
Sound Pressure Level dB(A) | 44~55 | 44~56 | 45~58 | 45~58 | 46~59 | 47~60 |
Operation Range (°C) | -25~43 | |||||
Max. Outlet Water Temp. (°C) | 60 | |||||
Water Proof Class | IPX4 | |||||
Electricity Shock Proof | Ⅰ | |||||
Net Dimensions (L×W×H) (mm) | 1338x450x1320 | 1338 x 450 x 1320 | 1338 x 450 x 1320 | 1338 x 450 x 1320 | 1338 x 450 x 1320 | 1338 x 450 x 1500 |
To Request Commercial Information Or More Details, Please Fill Out The Form & We Will Get Back To You Shortly .